Custom Steam Distributing Coils.
Custom steam distributing coils for commercial air handlers and ventilation equipment. Start with the existing coil measurements or submit a drawing through Coil Brief.
Steam Distributing coil · Illustrative construction
What does a steam distributing coil do?
A steam distributing coil heats passing air using steam. An inner distributing tube releases steam along the outer heating tube. As the steam condenses, it transfers heat through the tube walls and fins into the air.
This tube-within-a-tube arrangement helps distribute steam along the coil. The resulting liquid water, called condensate, must drain through the return connection. The illustration shows one possible arrangement with the steam and condensate connections on the same side.
//Coil selection
What matters when selecting a Steam Distributing coil?
The right coil depends on the heating requirement, steam conditions, condensate return, and installation requirements.
What to consider
Why it matters
Heating requirement
Heating load and available airflow
Steam conditions
Supply pressure, temperature, and system requirements
Internal distributing tubes
Confirm the existing construction and proposed steam path
Condensate return
Connection locations and return arrangement
Materials and environment
Material compatibility and environmental exposure
Fit and installation access
Dimensions, mounting, connections, and removal space
Replacing an existing coil? Start with its measurements or drawing.
Operating data is not required to begin a measurement-based replacement request. The proposed internal construction is confirmed during review.
Relative material cost. Final pricing depends on coil specifications.
Casing
The formed frame supports and protects the coil. Galvanized steel and stainless steel casing options are reviewed against the application and approved drawing.
Inner distributing tubes, outer heating tubes, and header construction are reviewed for your application. Final materials and construction are confirmed in the approved drawing.
Steam distribution and condensate drainage
The internal tube distributes steam. The outer tube transfers heat and collects the resulting condensate.
Inner distributing tube
Openings along the inner tube release steam into the surrounding heating tube, spreading the steam supply along its length.
Outer heating tube
Steam condenses around the inner tube and releases heat through the outer tube and fins into the passing air.
Condensate drainage
The liquid water must leave the coil through the return. Coil orientation, steam traps, and the condensate-return system affect drainage.
The “non-freeze” name does not guarantee protection from freezing. Trapped condensate can still freeze when conditions allow.
Replacing a standard steam coil with a steam distributing design requires review of the application and installation. Contact Rowform to discuss a change in construction.
Replacement and order details
OEM replacements
Discontinued or unknown model? Start with measurements or a drawing.
Independent aftermarket replacements. Rowform is not affiliated with or endorsed by these brands.
You can submit a replacement request even if the original steam distributing coil is discontinued or the equipment model is unknown. Use the measurement pathway to document the existing coil, or submit an existing drawing through the drawings pathway.
An equipment brand or model alone does not confirm compatibility. Review the proposed dimensions, connections, materials, and internal construction for the individual replacement.
Rowform reviews the submitted coil details to determine whether a custom replacement can be supplied. The review includes dimensions, construction, and the steam and condensate connection layout.
Rowform supplies independent aftermarket replacements and is not affiliated with or endorsed by these equipment brands. Brand pages do not establish compatibility with every model.
Coil dimensions
Enter the overall, casing, and fin dimensions and coil depth requested in the measurement pathway. Use the measurement guidance or contact Rowform if a detail is unclear.
Steam and condensate connections
Provide the requested connection diameters, locations, and orientation from the existing coil. Check the proposed connection layout on the engineering drawing before approval.
Tube and fin construction
Enter the requested materials, rows, fins per inch, and tube counts from the existing coil. Do not guess at construction details that are hidden or unclear.
Internal design
The internal design matters as well as the outer dimensions. Existing documentation can provide optional support for the review. The illustration does not establish the internal construction of your replacement.
Choose the measurement pathway or the separate drawings pathway. Equipment brand and model, nameplate photos, connection photos, and supporting drawings are optional in the measurement pathway; you do not need to supply all of them.
For requests based on operating requirements, email [email protected].
Coil protection
Nano Coating, E-Coating, and optional hydrophilic fin treatment.
Select No Coating, Nano Coating, or E-Coating in the Coil Protection step of Coil Brief. Use Help me choose to compare Nano Coating and E-Coating for your coil’s environment.
Nano Coating is a clear coating; E-Coating provides an epoxy barrier. Hydrophilic fin treatment is a separate optional add-on that helps water spread and drain from the fins. Added treatments are priced in your quote.
Your quote separates manufacturing and transit estimates.
Your quote includes estimated manufacturing and transit times based on the reviewed specifications, quantity, and freight service. Transit begins after dispatch and does not include production time.
Estimates are not guaranteed delivery dates. Expedited production and shipping are not currently available.
12-month limited warranty
Coverage begins at documented delivery.
Coverage starts at documented delivery and covers qualifying manufacturing and material defects. Registration is not required.
Freezing damage and corrosion caused by unsuitable fluids, chemicals, or environmental exposure are excluded. Review the full coverage, exclusions, and remedies before ordering.
Check the proposed dimensions, steam and condensate connection locations, materials, construction, and any selected coating on the engineering drawing before approving it. Contact Rowform about discrepancies before approval.
Submitting a Coil Brief does not place an order or require payment. Coil Record keeps your project documents and order updates together.
A steam distributing coil uses an inner tube to distribute steam along an outer heating tube. Steam releases heat as it condenses, warming the air passing across the fins. The liquid condensate leaves through the return connection.
The internal steam path differs. Steam distributing construction uses an inner distributing tube within the outer heating tube. Matching the casing dimensions alone does not establish an equivalent replacement. Share existing construction details or drawings when available.
No. Steam distributing coils are sometimes called non-freeze coils, but trapped condensate can still freeze. Steam supply, controls, air removal, condensate drainage, and the return system must suit the application.
Use Coil Brief to provide the requested dimensions, tube and fin details, and connection sizes and locations, or submit an existing drawing through the drawings pathway. Equipment information and supporting photos can help with review. If a detail is hidden or unclear, contact Rowform for help.
You can begin a measurement-based replacement request with the existing coil measurements or drawing. Coil Brief does not require operating performance data for that pathway. If operating conditions are changing or you need selection based on performance, email [email protected].
Yes. Submit the existing coil measurements or drawing. Rowform reviews the dimensions, construction, and connection arrangement to determine whether a custom replacement can be supplied.
Yes. Review and approve the engineering drawing, checking dimensions, steam and condensate connection locations, materials, construction, and any selected coating. Contact Rowform about discrepancies before approving it. Coil Record keeps your project documents and order updates together.
Rowform’s limited coil warranty lasts 12 months from documented delivery, with no registration required. It covers qualifying manufacturing and material defects, subject to the Terms of Service. Freezing damage and corrosion caused by unsuitable fluids, chemicals, or environmental exposure are excluded. Review the full warranty for coverage, exclusions, and remedies.
Your quote includes estimated manufacturing and transit times based on the reviewed specifications, quantity, and freight service. Transit starts after dispatch and does not include production time. Estimates are not guaranteed delivery dates. Expedited production and shipping are not currently available.