Custom Steam Distributing Coils.

Custom steam distributing coils for commercial air handlers and ventilation equipment. Start with the existing coil measurements or submit a drawing through Coil Brief.

Start a Coil Brief

2–3 minutes with measurements ready.

Front-facing steam distributing coil with a galvanized frame, aluminum fins, nine aligned tube runs, a copper header, and two connections pointing left.
Steam Distributing coil · Illustrative construction

What does a steam distributing coil do?

A steam distributing coil heats passing air using steam. An inner distributing tube releases steam along the outer heating tube. As the steam condenses, it transfers heat through the tube walls and fins into the air.

This tube-within-a-tube arrangement helps distribute steam along the coil. The resulting liquid water, called condensate, must drain through the return connection. The illustration shows one possible arrangement with the steam and condensate connections on the same side.

Coil selection

What matters when selecting a Steam Distributing coil?

The right coil depends on the heating requirement, steam conditions, condensate return, and installation requirements.

What to considerWhy it matters
Heating requirementHeating load and available airflow
Steam conditionsSupply pressure, temperature, and system requirements
Internal distributing tubesConfirm the existing construction and proposed steam path
Condensate returnConnection locations and return arrangement
Materials and environmentMaterial compatibility and environmental exposure
Fit and installation accessDimensions, mounting, connections, and removal space

Replacing an existing coil? Start with its measurements or drawing.

Operating data is not required to begin a measurement-based replacement request. The proposed internal construction is confirmed during review.

Materials and construction

Explore materials for your steam distributing coil.

Front-facing steam distributing coil with a galvanized frame, aluminum fins, nine aligned tube runs, a copper header, and two connections pointing left.
FinsTubesCasing

Relative upfront cost: $ lower · $$ moderate · $$$ higher

Fin materials

  • Illustrative aluminum fin sample showing thin parallel sheets.

    Aluminum

    Relative upfront cost: 1 of 3.

  • Illustrative copper fin sample showing thin parallel sheets.

    Copper

    Relative upfront cost: 2 of 3.

  • Illustrative stainless steel fin sample showing thin parallel sheets.

    Stainless steel

    Relative upfront cost: 3 of 3.

Tube materials

  • Illustrative copper tube sample showing the hollow passage and tube wall.

    Copper

    Relative upfront cost: 1 of 3.

  • Illustrative stainless steel tube sample showing the hollow passage and tube wall.

    Stainless steel

    Relative upfront cost: 2 of 3.

  • Illustrative copper nickel tube sample showing the hollow passage and tube wall.

    Copper nickel

    Relative upfront cost: 3 of 3.

  • Illustrative titanium tube sample showing the hollow passage and tube wall.

    Titanium

    Relative upfront cost: 3 of 3.

Relative material cost. Final pricing depends on coil specifications.

Illustrative galvanized steel casing corner showing its folded edges.

Casing

The formed frame supports and protects the coil. Galvanized steel and stainless steel casing options are reviewed against the application and approved drawing.

Inner distributing tubes, outer heating tubes, and header construction are reviewed for your application. Final materials and construction are confirmed in the approved drawing.

Steam distribution and condensate drainage

The internal tube distributes steam. The outer tube transfers heat and collects the resulting condensate.

  • Inner distributing tube

    Openings along the inner tube release steam into the surrounding heating tube, spreading the steam supply along its length.

  • Outer heating tube

    Steam condenses around the inner tube and releases heat through the outer tube and fins into the passing air.

  • Condensate drainage

    The liquid water must leave the coil through the return. Coil orientation, steam traps, and the condensate-return system affect drainage.

The “non-freeze” name does not guarantee protection from freezing. Trapped condensate can still freeze when conditions allow.

Replacing a standard steam coil with a steam distributing design requires review of the application and installation. Contact Rowform to discuss a change in construction.

Replacement and order details

OEM replacements

Discontinued or unknown model? Start with measurements or a drawing.

Independent aftermarket replacements. Rowform is not affiliated with or endorsed by these brands.

Coil protection

Nano Coating, E-Coating, and optional hydrophilic fin treatment.

Production and delivery

Your quote separates manufacturing and transit estimates.

12-month limited warranty

Coverage begins at documented delivery.

Review your drawing before production.

Check the proposed dimensions, steam and condensate connection locations, materials, construction, and any selected coating on the engineering drawing before approving it. Contact Rowform about discrepancies before approval.

Submitting a Coil Brief does not place an order or require payment. Coil Record keeps your project documents and order updates together.

Start a Coil Brief

Frequently asked questions.